Smoke and Co Detector

Feature of Smoke and carbon monoxide alarm

1. No need to connect with fire alarm controller, battery powered, economical
2. Built-in buzzer, strong sound after alarm
3. Simple installation, no need to debug
4. Low electrode consumption, can work for several years under normal conditions

Categories: ,

Description

Description of Smoke and Co Detector:

The Smoke and Co Detectors are photo-electronic detector uses a state of-the-art optical sensing chamber.

This detector is designed to provide open area protection and to be used with most conventional fire alarm panel.

Two LEDs on each detector provide local 360° visible alarm indication.

They flash every six seconds indicating that power is applied and the detector is working properly.

The LEDs latch on in alarm. LEDs will be off when a trouble condition exists indicating that the detector sensitivity is outside the listed limit.

The alarm can be reset only by a momentary power interruption.

The detector that initiated the alarm condition will have its red LED and relays latched until reset by panel.

kidde carbon monoxide detector

first alert smoke detector

Installation of Smoke and Co Detector

1. Fix the detector chasis on the ceiling with screw.
2. Open the detectors upper case, assemble the battery and fix the detector on the chasis.
2. Press test button to perform self-test to make sure it work well.
3. Smoke detector inspection: perform usual inspection to make sure it work well. normally,
the indicator light will blink every 2 seconds. When the smoke density exceed the standard, it will send out firm alarm.
4. Battery inspection: if the battery voltage is too low, it will sound lightly every 1 minute till
the battery run out of energy.

smoke detector installation

instal smoke detector

What is Smoke and Co Detector?

Household Smoke and Co Detector are generally installed in the living room, study or bedroom, but some families install them in the kitchen or the installation location is too close to the kitchen. The kitchen itself is a place with a lot of smoke, heat and humidity. The Smoke alarm is installed in Here, not only a false alarm may occur, but also its service life will be affected.

The above briefly mentioned several reasons that may cause household Smoke and carbon monoxide alarm to keep ringing. In this case, first check the entire room to make sure there is no fire. If it is a false alarm, troubleshoot according to the content of this article. If you can’t solve it by yourself, contact the manufacturer in time for handling.

Features and advantages of Smoke and Co Detector

The stand-alone smoke fire detection alarm can detect the early characteristics of a fire, send out a fire alarm signal, and provide instructions for evacuation and prevention of fire.
Advantages of independent smoke fire detection alarm:

1. No need to connect with fire alarm controller, battery powered, economical
2. Built-in buzzer, strong sound after alarm
3. Simple installation, no need to debug
4. Low electrode consumption, can work for several years under normal conditions

fire detector
fire detector

The specification of Smoke and Co Detector

Model No.:Smoke and Co Detector

  • The world’s first UL new standard approval 10 years battery smoke alarm
    Photoelectric chamber for easily detect
    Loud>85dB(A)alarm signal @3M
    Low battery detect
    Hush function
    Fault warning
    Easily install with mounting bracket
    10-hour non-disturb mode under low battery status avoiding undesired noise
    Buzzer:wiring connetion and spring touch